Categories | High Voltage Epoxy Resin Insulator |
---|---|
Brand Name: | QIUPU |
Model Number: | JYN2-35kV-630A |
Certification: | IEC |
Place of Origin: | WENZHOU |
MOQ: | 100PCS |
Payment Terms: | T/T, Western Union |
Supply Ability: | 100000PCS/Month |
Delivery Time: | 7 Days |
Packaging Details: | Cartons |
Material: | Casting Resin/Plastic |
Color: | White |
Higth: | 370mm |
Creppage Distance: | 800mm |
Rate Voltage: | 35kV |
Frequency Voltage: | 98kV |
Flexural Strength: | 8kN |
Company Info. |
WENZHOU QIUPU ELECTRIC POWER CO., LTD. |
Verified Supplier |
View Contact Details |
Product List |
JYN2-35kV 630A Spolt Bushings Insulators with Indoor High Voltage Switchgear
General Description of the Contact BOX Series Contact Box Series
1. The contact box is the pressure gel molding structure of epoxy
resin APG process, which is used for various kinds of handcart type
switchgear, acting as insulation isolation and connection
transition.
The contact box is formalised by ecoxy with APG technologies, it is
used for integration and conversion of
Various switch trucks.
2. Model meaning
Model Meaning Operation Configuration
1. Altitude not exceeding 1000 M
Altitude: < 1000M;
2. ambient temperature + 40 °C to 10 °C;
Ambient temperature: + 40 °C to 10 °C;
3. When the air temperature is + 20 °C, the relative humidity does
not exceed 95 %
The relevant human dimension call not be more than 95 % at + 20 °C
ambient phase;
4. Gas, Steam, dust without seriously affecting the insulation of
the contact box
No exploration or corrosive submission.
Technical Data & Requirements Requirement
Technical data and requirements 1. Contact box and contact should
be able to withstand frequency test voltage(effectiveness) 42 KV, 5
minutes, lightning shock(peak) 75 KV;
The label contact to earth call with power freedom test volume of
42 KV for 5 minutes and
Lightning impact vplage(peace value) of 75KV;
2. The temperature rise of the end of the contact box at the end of
the line under long-term operation does not exceed 65 ℃ under the
rated electricity;
The experience of lead-out final call not more than 65 °C if the
contact box is used for long time in rate
Current con
Item | Technical data | ||||||||||||
Rated voltage (KV) | 40.5 | ||||||||||||
Rated frequency(Hz) | 50 | ||||||||||||
Insulator(capacity) | insulating | Frequency withstand voltage 5 min (KV) | 100 | ||||||||||
Frequency withstand voltage 1 min (V) | 2000 | ||||||||||||
Lighting impulse withstand voltage (KV) | 185 | ||||||||||||
Local discharge (pc) | ≤10 | ||||||||||||
Dispute bend (N) | ≥1000 | ||||||||||||