Sign In | Join Free | My myecer.com
myecer.com
Products
Search by Category
Home > Steel >

Fiberglass Insulation Thermocouple Cable Type K 100 M Extension Class I

Categories Thermocouple Cable
Brand Name: Ohmalloy/OEM
Model Number: SP-K-FB-FB-0.71
Certification: IEC/ASIN/JIS
Place of Origin: shanghai
MOQ: 100 meters
Price: USD 0.5~10/meter
Payment Terms: L/C, T/T, , MoneyGram,paypal
Supply Ability: 1000meter/day
Delivery Time: 5-8 working days after payment confirmed
Packaging Details: Spool+paper case + wooden case/plastic packing+papre case+ wooden box outside(or customized)
Product Name: Fiberglass Insulation Thermocouple Type K 100 m Extension Cable
Material: + Chromel -Alumel
Accuracy: Class I
Color: + Yellow -Red(customized)
Package: Spool+waterproof carton (100meter/roll)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Fiberglass Insulation Thermocouple Cable Type K 100 M Extension Class I

    Fiberglass Insulation Thermocouple Type K 100 m Extension Cable 0.71 mm x 2

    TYPE K (CHROMEL vs ALUMEL) is used in oxidizing, inert or dry reducing atmospheres. Exposure to vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres. Reliable and accurate at high temperature.


    1. Product Specification


    1. Chemical Composition

    MaterialChemical composition (%)
    NiCrSiMnAl
    KP(Chromel)9010
    KN(Alumel)951-20.5-1.51-1.5

    2. Physical Properties and Mechanical Properties

    Material

    Density(g/cm3)


    Melting point℃)


    Tensile Strength(Mpa)


    Volume resistivity(μΩ.cm)


    Elongation rate (%)

    KP(Chromel)8.51427>49070.6(20℃)>10
    KN(Alumel)8.61399>39029.4(20℃)>15

    3. EMF Value Range at Different Temperature

    MaterialEMF value Vs Pt(μV)
    100℃200℃300℃400℃500℃600℃
    KP(Chromel)2816~28965938~60189298~937812729~1282116156~1626619532~19676
    KN(Alumel)1218~12622140~21802849~28933600~36444403~44635271~5331

    EMF value Vs Pt(μV)
    700℃800℃900℃1000℃1100℃
    22845~2299926064~2624629223~2941132313~3252535336~35548
    6167~62477080~71607959~80598807~89079617~9737

    2. How To Choose Thermocouple


    TypeInsulation materialCODEInner ShieldingCODEJACKETCODEOut shieldingCODEPairssolidEarth wireStranded
    KFEPFPFEPFP00.2mmEcross section+R
    TPFAFAAl foilALPFAFAcopper wireCU20.3mm
    EPVC 70℃LPcopper wireCUPVC 70℃LPTinned copperTC30.5mm
    JPVC 105℃HPTinned copperTCPVC 105℃HPNickel plated copperNC40.75mm
    NFiberglass 400℃BLNickel plated copperNCFiberglass 400℃BLSilver plated copperAC51.0mm
    SCFiberglass600℃BMSilver plated copperACFiberglass600℃BMSS 304 wireSS61.5mm
    Fiberglass700℃BHFiberglass700℃BH
    MICA FIBER 650℃MA
    KCAVitreous Silica 800℃VSSS 304 wireSSVitreous Silica 800℃VS72.5mm
    KCBSilica fiber1000℃SVInconel 600 wire600Silica fiber1000℃SV8
    RTDCeramic fiber1200℃CFInconel 625 wire625Ceramic fiber1200℃CF9
    PTFEPTPTFEPT
    ETFEETETFEET
    KAPTONKPKAPTONKP
    Silcone rubberSRSilcone rubberSR
    RubberRURubberRU
    PEPEPEPE

    3. Size and Insulation Material Reference


    Size and Insulation Material Reference
    TypeCross-Section
    (mm2)
    DiameterInsulation Material/ Jacket MaterialShield
    AWG (SingleCore)mm
    (Multi-Core)
    SC RC BC KCA KCB KX NC NX EX JX LX0.07-1 x 0.30Ceramic Fiber(-60,+1200℃) Vitreous Silica(-60,+800℃) Mica(-60,+650℃) Silica Fiber(-60,+1000℃) High Temperature Fiber(-60,+600℃) Fiberglass(-60,+450℃) PolyimideTape/Kapton(-60,+260℃) PTFE(-60,+275℃) PFA(-60,+275℃) FEP(-60,+205℃) SiliconeRubber(-60,+200℃) PVC(-25,+105℃) PVC(-25,+70℃)Nickel Chrome Alloy Wire Braiding; Stainless Steel Braiding; Tin-plated Copper Braiding; Aluminum-plastic Tape Wraping; Copper Tape Wraping; Aluminum Foil Wraping
    0.22247 x 0.20
    0.35225 x 0.30
    0.402113 x 0.20
    0.50207 x 0.30
    0.502019 x 0.20
    0.75197 x 0.37
    0.751924 x 0.20
    1.001814 x 0.30
    1.001824 x 0.20
    1.34167 x 0.49
    1.341619 x 0.30
    1.50167 x 0.52
    1.501621 x 0.30
    2.001419 x 0.366
    2.001428 x 0.30
    2.501319 x 0.41
    2.501336 x 0.30

    4 Color/Standard Reference


    6. Questions and Answers


    Q1:How can I contact with your company?

    A1:We have multiple communication channels : Tel/ :+86-15826530281


    Q2:Do you provide free samples?

    A2:Yes,we can provide free samples for your testing,but buyer should bear the shipping costs.


    Q3:What is your payment terms?

    A3:30% in advance,balance after receiving the copy of B/L. T/T,L/C,,Paypal is OK.


    Q4:What is your lead time?

    A4:On normal condition,the lead time is 7 days after the payment. Special order or quantity is subject to the negotiation.


    Q5:What is your working time?

    A5: Monday to Firday: 9:00-12:00,13:30-17:30, rest in weekend.


    Quality Fiberglass Insulation Thermocouple Cable Type K 100 M Extension Class I for sale
    Send your message to this supplier
     
    *From:
    *To: Ohmalloy Material Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category:
    Inquiry Cart 0