Model Number: KP-LN9
standard: IEC 60335-1 Clause 25.15
operation time: 25
Pull weight: 20N * 2, 30N * 2
Torque weight: 2N(0.1Nm) * 1, 5N(0.25Nm) * 1, 7N(0.35Nm) * 1
Test speed: 1 times/s
Torque time: 0.01s-99h99min
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Cable / Cord Anchorage Torque Tester IEC 60335-1 Clause 25.15 / IEC60950-1-class3.2.6


    Cord Anchorage Torque Tester / Power Cord Tension and Torque Tester


    Description:
    This device is design and manufactured accord to the requirements of IEC 60335-1 clause 25.15,
    GB2486 and relevant standards. It is use to perform tension and torque test on the power cord. It is
    used to test the strength of connections.
    Accordding to the standard IEC 60335-1 Clause 25.15
    --“Appliances provided with a supply cord, and appliances intended to be permanently connected to
    fixed wiring by a flexible cord, shall have a cord anchorage. The cord anchorage shall relieve
    conductors from strain, including twisting, at the terminals and protect the insulation of the
    conductors from abrasion.
    It shall not be possible to push the cord into the appliance to such an extent that the cord or
    internal parts of the appliance could be damaged.
    Compliance is checked by inspection, by manual test and by the following test.
    A mark is made on the cord while it is subjected to the pull force shown in Table 12, at a
    distance of approximately 20 mm from the cord anchorage or other suitable point.
    The cord is then pulled, without jerking, for 1 s in the most unfavourable direction with the force
    specified. The test is carried out 25 times.
    The cord, unless on an automatic cord reel, is then subjected to a torque that is applied as close
    as possible to the appliance. The torque is specified in Table 12 and is applied for 1 min.


    During the tests, the cord shall not be damaged and shall show no appreciable strain at the
    terminals. The pull force is reapplied and the cord shall not be longitudinally displaced by more
    than 2 mm.”


    Specifications

    Power supply220VAC 50Hz
    Pull weight20N * 2, 30N * 2
    Torque weight2N(0.1Nm) * 1, 5N(0.25Nm) * 1, 7N(0.35Nm) * 1
    Test times0-9999, default 25 times
    Test speed1 times/s
    Torque time0.01s-99h99min

    Technical parameter

    1, working power: AC220V 50HZ

    2, tension: 30N, 60N, 100N (20N, 30N weight each two)

    3, torque: 0.1,0.25,0.35N.M (5N, 12.5N, 17.5N weight each one)

    4, the number of tests: 0 ~ 999999 can be preset

    5, tension frequency: 1 s/time (each return including tension and non-tensile time)

    6, torque arm: 20mm

    7, torque time: 0-99 hours 59 minutes 59 seconds

    8, fixture: tension fixture and torque fixture combination,through bearing to reduce friction during torque test

    • Tension and torque match table

    GB4706.1 Table 12

    Appliance quality/kgTension/Ntorque/N.mTension+torque
    ≦1300.130N+5N
    1< and ≦4600.252*30N+12.5N
    >41000.35100N+17.5N

    Preparation before the test

    1, First of all, equipment should be placed in the horizontal plane, can not have clear tilt, and then lock the caster brake.

    2, For the sample selection of the tension weight and torque weight, For example, toaster is 2.5kg, then choose 60N tension weight (2 pc s of 30N) and 12.5N torque weight.

    3, Sample Installation: As shown below, the sample installation must ensure that the tension weight and torsion weight lanyard in a stretched state, and the specimen against the outside of the fixture, power cord clamping end is in a level state. Methods of operation are as follows:

    3.1, adjust [up and down adjustment hand wheel], to keep sample power cord pinout and the power cord clamp end in a level state. Hold the specimen against the outside of the fixture and clamp the power cord.

    3.2, bounce 【jig release】 button, the light is on at this time, hang up the torsion weight, catch the torsion weight when the torsion strap is tightened, and ensure that the clamping end of the power cord is still in the horizontal state at this moment.

    3.3,Press [start], when the pull weight tray at the lowest point [stop], put a height pad. Put the tension weight on the height pad, and then straighten the tension lanyard to hang the weight hanger, and make tension lanyard in a stretched state by adjusting the tension wheel.

    2, Clamp a sample, mark the position of 20mm at the pinout

    3, Pre-set standards requirement [test times] and [test time].

    4, press【reset】, clear current【test times】.


    Normal test

    1, Remove height pad, press 【Start】, the device starts tension test.When reaching preset 【test times】it will automatically release torque weight and starts torque test.When reaching【test time】, manually lift the torsion weight to complete whole test.

    2, Using a caliper to measure the length of the symbol from the exit, the reading minus 20mm is the amount of elongation after the test.

    3, For a second test, we must press reset button to execute.

    Preset and parameters

    Counter / Timer: Press [SET] for 5 seconds to enter setting mode → When the display mode is [LCK] = [COD], enter the following parameter settings → press [SET] and ▲ or ▼ to select the mode → and so on → finally return to the measurement Status and complete setup process. Press <to select preset time / test times, then press ▲ up or ▼ to select needed value, then press [SET] to confirm.
    Timer
    LCK0000
    MOD0000Timing control modePAU
    Panel lock LKYNOPower outage memoryYES
    MODTIMOutput mode OUTF
    Timing mode U-DUDelay unit UNT999999
    Time Range RAN99.59.99Delay time TIM000000

    Maintenance

    1. Before operation,check if the fasteners is loose;lock the loose one.

    2. Turn off the power when not operating.