Categories | Solar Inverter |
---|---|
Output Power: | 1 - 200KW |
Output Type: | Single |
Type: | DC/AC Inverters |
Key Features:
1.Pure sine wave output
2.The charging current is big up to 85 Amp
3.Output power factor is 0.9-1
4.Output socket optional
5.Battery type can be select
6.Output voltage and frequency can be set
7.Charge current can adjust
Technical Specification:
MODEL | IG3115C 1000-6000W Pure Sine wave Output Inverter | |||||||
1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | ||
Input Wave form | Sine wave (utility or generator) | |||||||
Nominal Voltage | 120Vac 230Vac | |||||||
Low voltage re trip | 90v ±4% & 184v/154v ±4% | |||||||
Low voltage re engage | 100v ±4% & 194v/164v±4% | |||||||
High voltage re trip | 140v ±4% & 253v ±4% | |||||||
High voltage re engage | 135v ±4% & 243v±4% | |||||||
Max Input AC Voltage | 150VAC 270VAC | |||||||
Nominal Input Frequency | 50Hz/ 60Hz (auto detection) | |||||||
Low freq trip | 47Hz for 50Hz,57Hz for 60Hz | |||||||
High freq trip | 55Hz for 50Hz,65Hz for 60Hz | |||||||
Output Wave form | (Bypass mode)same as input | |||||||
Over-Load Protection | Circuit breaker | |||||||
Short circuit Protection | Circuit breaker | |||||||
Transfer Switch Rating | 30Amp or 40Amp | |||||||
Efficiency on line transfer model | ≥95%+ | |||||||
Line transfer time | 10ms Typical | |||||||
Bypass without battery connected | Yes | |||||||
Max bypass current | 30 amp or 40 amp | |||||||
Bypass over load current | 30 amp or 45 amp:Alarm | |||||||
Inverter specification/output | ||||||||
Output wave form | Pure sine wave | |||||||
Output continuos power watts | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | |
Output continuos power VA | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 600 | |
Power factor | 0.9-1.0 | |||||||
Nominal Output Voltage rms | 120/230VAC | |||||||
Output Voltage regulation | +/- 10%rms | |||||||
Output frequency | 50Hz ± 0.3Hz or 60Hz ± 0.3Hz | |||||||
Safety Certification | >88% | |||||||
Surge ratings | 3000 | 4500 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Short circuit protection | Yes,fault after 1 secs | |||||||
Inverter specification/input | ||||||||
Nominal input voltage | 12V | 24V | 48V | |||||
Minimum start voltage | 10V | 20V | 40V | |||||
Low battery alarm | 10.5V | 21V | 42V | |||||
Low battery trip | 10V | 20V | 40V | |||||
High voltage alarm | 16V | 32V | 64V | |||||
Power saver | Below 25 watts when enabled | |||||||
Power saver | Same switched on/off on remote | |||||||
Charger mode specification | 95-127VAC | 194-243VAC/164-243VAC(W) | ||||||
Input voltage range | Dependent on battery type | |||||||
Output voltage | 35A/70A MAX | |||||||
Charge current | 0-15.7v for 12v(*2 for 24v;*4 for 48v) | |||||||
Battery initial voltage for start up | 15.7v for 12v(*2 for 24v;*4 for 48v) | |||||||
Over charge protection shutdown | ||||||||
Charger curves(4stage constant curren)battery types | ||||||||
4 step digital controlled progressive charge | ||||||||
Battery type | Fast V Fast V(*2 for 24v;*4 for 48v) | |||||||
Gel U.S.A | 14.0 13.7 | |||||||
A.G.M. 1 | 14.1 13.4 | |||||||
A.G.M. 2 | 14.6 13.7 | |||||||
Sealed lead acid | 14.4 13.6 | |||||||
Gel euro | 14.4 13.8 | |||||||
Open lead acid | 14.8 13.3 | |||||||
Calcium | 15.1 13.6 | |||||||
De-sulphation | 15.5 for 4 hrs | |||||||
Remote control/RS232/USB | Yes. Optional | |||||||
Size: in mm | 3 1000/1500Model:362*218*179mm³ | |||||||
2000/3000Model:442*218*179mm³ | ||||||||
4000/5000/6000Model:598*218*179mm³ | ||||||||
Weight | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | |
16KG |